Reliance
Pro/tran® Surface Mount Transfer Switches
Reliance Controls website
Indoor
Surface Mount Transfer Switches
Designed for fast installation in residential and
commercial applications
18-inch flexible conduit whip attaches easily to
load center
Rugged powder-coated steel cabinet
Six combination 1/2-inch and 3/4-inch knockouts
Resettable branch rated circuit breakers
Non-defeatable (break-before-make) double-throw switches
Some models feature exclusive Reliance wattmeters with accuracy
of ± 3%
throughout the entire range
Models with a power inlet on the front also include a cover for
the power inlet
opening that facilitates hardwiring
Models without a power inlet on the front include a covered opening
that
permits the installation of a power inlet for cord connection directly
to the
transfer switch
A wattmeter panel
(WP7500) is available for models without meters\
Optional hinged
covers made of high-impact clear plastic to protect from
accidental contact with transfer switch (CK6 for 4- and 6-circuit models,
CK10 for 8- and 10-circuit models\
Optional flush kit
(KF6 for 4- and 6-circuit models, KF10 for 8- and 10-circuit
models)
Optional flanged
power inlets for making connections to hardwire Pro/Tran
models (KF6 for 4- and 6-circuit models, KF10 for 8- and 10-circuit
models)![]()
Optional power inlet
boxes
Ask This Old House Transfer Switch Installation Video
| Indoor Surface Mount Cord Connected or Hardwire | |||
|---|---|---|---|
| 20216A | 30216A | 30310A | |
| Max Watts | 5000 | 7500 | 7500 |
| Max Single Pole Circuits |
6 | 6 | 10 |
| Max Double Pole Circuits |
1 | 1 | 5 |
| Max Combined Load @125VAC |
40A | 60A | 60A |
| Max Combined Load @250VAC |
20A | 30A | 30A |
| Max Load/Circuit from Generator |
4/15A 2/20A |
4/15A 2/20A |
6/15A 4/20A |
| Max Load/Circuit from Load Center |
20A | 20A | 20A |
| Power Inlet, NEMA | L14-20 | L14-30 | L14-30 |
| Minimum Rec. Cord Size | 12 Ga. | 10 Ga. | 10 Ga. |
| Conduit Length | 18" | 18" | 18" |
| Conduit, Trade Size | 3/4" | 3/4" | 1" |
| Wattmeters | yes | yes | yes |
| Cabinet Type, NEMA | 1 | 1 | 1 |
| Indoor Surface Mount Hardwire | ||||
|---|---|---|---|---|
| 31404B | 31406B | 30408B | 31410B | |
| Max Watts | 7500 | 7500 | 7500 | 7500 |
| Max Single Pole Circuits |
4 | 6 | 8 | 10 |
| Max Double Pole Circuits |
1 | 1 | 4 | 5 |
| Max Combined Load @125VAC | 60A | |||
| Max Combined Load @250VAC | 30A | |||
| Max Load/Circuit from Generator |
4/15A -- |
4/15A 2/20A |
6/15A 2/20A |
6/15A 4/20A |
| Max Load/Circuit from Load Center |
20A | |||
| Conduit Length | 18" | |||
| Conduit, Trade Size | 3/4" | 1" | ||
| Wattmeters | no | no | yes | no |
| Cabinet Type, NEMA | 1 | |||
Outdoor
Surface Mount Transfer Switches - Pro/Tran R Series (NEMA 3R)
Ideal for outdoor installation in
residential and commercial
applications
Gasketed steel cabinet is
powder-coated
Padlockable cover
Will accommodate generator cord
with cover closed
16-inch length of flexible
non-metallic, liquid-tight conduit
with fittings included
Six combination 1/2-inch and
3/4-inch knockouts (one on each
side, two on the bottom and two on the back)
Branch-circuit rated breakers
Heavy-duty power inlet
Non-defeatable (break-before-make) double-throw switches
125/250V models feature exclusive Reliance wattmeters with accuracy
of ± 3%
throughout the entire range
Ask This Old House Transfer Switch Installation Video
Outdoor Surface Mount Hardwire
| Outdoor Surface Mount Hardwire | |||||
|---|---|---|---|---|---|
| R15114B | R20216B | R30114B | R30216B | R30310B | |
| Max Watts | 1875 | 5000 | 7500 | 7500 | 7500 |
| Max Single Pole Circuits | 4 | 6 | 4 | 6 | 10 |
| Max Double Pole Circuits | -- | 3 | -- | 3 | 5 |
| Max Combined Load @125VAC | 15A | 40A | 60A | 60A | 60A |
| Max Combined Load @250VAC | -- | 20A | 30A | 30A | 30A |
| Max Load/Circuit from Generator | 4/15A -- |
4/15A 2/20A |
4/15A -- |
4/15A 2/20A |
6/15A 4/20A |
| Max Load/Circuit from Load Center | 20A | ||||
| Power Inlet, NEMA | 5-15 | L14-20 | L5-30 | L14-30 | L14-30 |
| Minimum Cord Size | 14 Ga. | 12 Ga. | 10 Ga. | 10 Ga. | 10 Ga. |
| Conduit Length | 16" | ||||
| Conduit, Trade Size | 1/2" | 3/4" | 3/4" | 3/4" | 1" |
| Wattmeters | no | yes | no | yes | yes |
50A
Indoor Surface, Indoor Flush and Outdoor (NEMA 3R)
Same features of the Pro/Tran
line
Pre-wired and have a wiring
compartment for hardwire
connection to a remote power
inlet
Rated at 50A, they can handle
generators up to 12,500 watts
Easy to install
Easy to operate
Ask This Old House Transfer Switch Installation Video
![]()
| 50A Indoor Surface / Indoor Flush | |||||
|---|---|---|---|---|---|
| 51406B/ 51406B +KF06 | 51406C/ 51406C + KF06 |
50408B / 50408B + KF10 | 51410B / 51410B + KF10 | 51410C / 51410C + KF10 | |
| Max Utility Input per Circuit | 20 | ||||
| Gen Power Inlet Included/Rating/ Config. | no | ||||
| Wattmeters | no | yes | yes | no | yes |
| Max Single Pole Circuits | 6 | 6 | 8 | 10 | 10 |
| Max Double Pole Circuits | 1 | 1 | 4 | 5 | 5 |
| Max Gen Input Per Circuit | 4/15A 2/20A |
4/15A 2/20A |
6/15A 2/20A |
6/15A 4/20A |
6/15A 4/20A |
| Max Gen Input (watts) | 12,500 | ||||
50A Outdoor (NEMA 3R)
| 50A Outdoor (NEMA 3R) | ||
|---|---|---|
| R50216B | R50310B | |
| Max Utility Input per Circuit |
20 | |
| Gen Power Inlet Included/Rating/ Config. |
yes/50A@250V CS6365 |
|
| Wattmeters | yes | |
| Max Single Pole Circuits |
6 | 10 |
| Max Double Pole Circuits |
1 | 5 |
| Max Gen Input Per Circuit |
4/15A 2/20A |
6/15A 4/20A |
| Max Gen Input (watts) | 12,500 | |
Q
Series
1-inch interchangeable circuit
breakers
A 30A double-pole circuit breaker
and a 20A double-pole circuit
breaker, to handle heavier loads
on the generator side, included
The balance of the circuit
breakers are single-pole 15A
The 15A circuits in the transfer
switch may be connected to 15A
or 20A circuits in the load center
Circuits are limited to 15A only on the generator side of the switch
Circuit breakers in the transfer switch are easily replaced (the
spaces
containing the 30A and 20A double-pole circuits may be replaced with
15 or
20A single-pole breakers)
Suitable for hardwire connection
Cord connection is facilitated with the optional flanged inlets
for direct
connection to the transfer switch or the PB Series power inlet box
for remote
connection
All Pro/Tran Q series models are UL listed for the following 15A,
20A and 30A
branch circuit breakers: Siemens Type QP; Square D HOM; Murray Type
MP;
Cutler-Hammer Series BR
Ask This Old House Transfer Switch Installation Video
| Q Series | |||
|---|---|---|---|
| Q506C | Q510C | Q510CE | |
| Max Watts | 12,500 | ||
| Max Single Pole Circuits |
6 | 10 | 10 |
| Max Double Pole Circuits |
3 | 5 | 5 |
| Max Combine Load @125VAC |
100A | ||
| Max Combine Load @250VAC |
50A | ||
| Standard Factory-installed Circuit Breakers (included) | 1/DP30 1/DP20 2/SP15 |
1/DP30 1/DP20 6/SP15 |
1/DP30 1/DP20 6/SP15 |
| Max Load/Circuit from Load Center |
1/DP30 & DP20 or SP20 in all other spaces | ||
| Optional Power Inlets | LL550F or L1430F | ||
| Optional Power Inlet Boxes | PB50 or PB30 | ||
| Min Recommended Cord Size |
6 Ga. (50A) or 10 Ga. (30A) | ||
| Conduit Length | 18" | ||
| Conduit Trade Size | 3/4" | 1" | |
All
Reliance Controls Corporation products are listed by Underwriters
Laboratories Inc.
Reliance has several products. Only selected products are featured here. For information on additional Reliance products please check Reliance's website or request information from ESA.
Additional websites from Reliance Controls:
Reliance Labs -
www.reliancelaboratories.com
The Home Protectors -
www.home-protectors.com
Technical Support -
http://support.reliancecontrols.com
Transfer Switch Safety -
www.transferswitches.com