ESA Logo



copyright © 2012 repesa.com
All Rights Reserved.

Reliance Pro/tran® Surface Mount Transfer Switches
                                                                                            
Reliance Controls website

 

 

30216AIndoor Surface Mount Transfer Switches

  Designed for fast installation in residential and
   commercial applications

  18-inch flexible conduit whip attaches easily to
   load center

  Rugged powder-coated steel cabinet

  Six combination 1/2-inch and 3/4-inch knockouts

  Resettable branch rated circuit breakers

  Non-defeatable (break-before-make) double-throw switches

  Some models feature exclusive Reliance wattmeters with accuracy of ± 3%
   throughout the entire range

  Models with a power inlet on the front also include a cover for the power inlet
   opening that facilitates hardwiring

  Models without a power inlet on the front include a covered opening that
   permits the installation of a power inlet for cord connection directly to the
   transfer switch

  A wattmeter panel (WP7500) is available for models without meters\

  Optional hinged covers made of high-impact clear plastic to protect from
   accidental contact with transfer switch (CK6 for 4- and 6-circuit models,
   CK10 for 8- and 10-circuit models\

  Optional flush kit (KF6 for 4- and 6-circuit models, KF10 for 8- and 10-circuit
   models)

  Optional flanged power inlets for making connections to hardwire Pro/Tran
   models (KF6 for 4- and 6-circuit models, KF10 for 8- and 10-circuit
   models)Stocked at ESA

  Optional power inlet boxes

  Ask This Old House Transfer Switch Installation Video

 

 

 

Indoor Surface Mount Cord Connected or Hardwire
  20216A 30216A 30310A
Max Watts 5000 7500 7500
Max Single
Pole Circuits
6 6 10
Max Double
Pole Circuits
1 1 5
Max Combined Load
@125VAC
40A 60A 60A
Max Combined Load
@250VAC
20A 30A 30A
Max  Load/Circuit
from Generator
4/15A
2/20A
4/15A
2/20A
6/15A
4/20A
Max  Load/Circuit
from Load Center
20A 20A 20A
Power Inlet, NEMA L14-20 L14-30 L14-30
Minimum Rec. Cord Size 12 Ga. 10 Ga. 10 Ga.
Conduit Length 18" 18" 18"
Conduit, Trade Size 3/4" 3/4" 1"
Wattmeters yes yes yes
Cabinet Type, NEMA 1 1 1

 

 

 

Indoor Surface Mount Hardwire
  31404B 31406B 30408B 31410B
Max Watts 7500 7500 7500 7500
Max Single
Pole Circuits
4 6 8 10
Max Double
Pole Circuits
1 1 4 5
Max Combined Load @125VAC 60A
Max Combined Load @250VAC 30A
Max  Load/Circuit
from Generator
4/15A
--
4/15A
2/20A
6/15A
2/20A
6/15A
4/20A
Max  Load/Circuit
from Load Center
20A
Conduit Length 18"
Conduit, Trade Size 3/4" 1"
Wattmeters no no yes no
Cabinet Type, NEMA 1

 

 

 

R20216BOutdoor Surface Mount Transfer Switches - Pro/Tran R Series (NEMA 3R)

  Ideal for outdoor installation in
   residential and commercial
   applications

  Gasketed steel cabinet is
   powder-coated

  Padlockable cover

  Will accommodate generator cord
    with cover closed

  16-inch length of flexible
   non-metallic, liquid-tight conduit
   with fittings included

  Six combination 1/2-inch and
   3/4-inch knockouts (one on each
    side, two on the bottom and two on the back)

  Branch-circuit rated breakers

  Heavy-duty power inlet

  Non-defeatable (break-before-make) double-throw switches

  125/250V models feature exclusive Reliance wattmeters with accuracy of ± 3%
   throughout the entire range

  Ask This Old House Transfer Switch Installation Video

 

Outdoor Surface Mount Hardwire

Outdoor Surface Mount Hardwire
  R15114B R20216B R30114B R30216B R30310B
Max Watts 1875 5000 7500 7500 7500
Max Single Pole Circuits 4 6 4 6 10
Max Double Pole Circuits -- 3 -- 3 5
Max Combined Load @125VAC 15A 40A 60A 60A 60A
Max Combined Load @250VAC -- 20A 30A 30A 30A
Max  Load/Circuit from Generator 4/15A
--
4/15A
2/20A
4/15A
--
4/15A
2/20A
6/15A
4/20A
Max  Load/Circuit from Load Center 20A
Power Inlet, NEMA 5-15 L14-20 L5-30 L14-30 L14-30
Minimum Cord Size 14 Ga. 12 Ga. 10 Ga. 10 Ga. 10 Ga.
Conduit Length 16"
Conduit, Trade Size 1/2" 3/4" 3/4" 3/4" 1"
Wattmeters no yes no yes yes

 

 

51410C50A Indoor Surface, Indoor Flush and Outdoor (NEMA 3R)

  Same features of the Pro/Tran
    line

  Pre-wired and have a wiring
   compartment for hardwire
   connection to a remote power
   inlet

  Rated at 50A, they can handle
   generators up to 12,500 watts

  Easy to install

  Easy to operate

 

  Ask This Old House Transfer Switch Installation Video

 

Stocked at ESA

 

 

 

50A Indoor Surface / Indoor Flush
  51406B/ 51406B +KF06 51406C/
51406C + KF06
50408B / 50408B + KF10 51410B / 51410B + KF10 51410C / 51410C + KF10
Max Utility Input per Circuit 20
Gen Power Inlet Included/Rating/ Config. no
Wattmeters no yes yes no yes
Max Single Pole Circuits 6 6 8 10 10
Max Double Pole Circuits 1 1 4 5 5
Max  Gen Input Per Circuit 4/15A
2/20A
4/15A
2/20A
6/15A
2/20A
6/15A
4/20A
6/15A
4/20A
Max Gen Input (watts) 12,500

 

 

50A Outdoor (NEMA 3R)
50A Outdoor (NEMA 3R)
  R50216B R50310B
Max Utility Input
per Circuit
20
Gen Power Inlet
Included/Rating/ Config.
yes/50A@250V
CS6365
Wattmeters yes
Max Single
Pole Circuits
6 10
Max Double
Pole Circuits
1 5
Max  Gen Input
Per Circuit
4/15A
2/20A
6/15A
4/20A
Max Gen Input (watts) 12,500

 

 

 

Q506CQ Series

  1-inch interchangeable circuit
   breakers

  A 30A double-pole circuit breaker
   and a 20A double-pole circuit
   breaker, to handle heavier loads
   on the generator side, included

  The balance of the circuit
   breakers are single-pole 15A

  The 15A circuits in the transfer
   switch may be connected to 15A
   or 20A circuits in the load center

 

 

  Circuits are limited to 15A only on the generator side of the switch

  Circuit breakers in the transfer switch are easily replaced (the  spaces
   containing the 30A and 20A double-pole circuits may be replaced with 15 or
   20A single-pole breakers)

  Suitable for hardwire connection

  Cord connection is facilitated with the optional flanged inlets for direct
   connection to the transfer switch or the PB Series power inlet box for remote
   connection

  All Pro/Tran Q series models are UL listed for the following 15A, 20A and 30A
   branch circuit breakers: Siemens Type QP; Square D HOM; Murray Type MP;
   Cutler-Hammer Series BR

  Ask This Old House Transfer Switch Installation Video

 

 

Q Series

Q506C Q510C Q510CE
Max Watts 12,500
Max Single
Pole Circuits
6 10 10
Max Double
Pole Circuits
3 5 5
Max Combine
Load @125VAC
100A
Max Combine
Load @250VAC
50A
Standard Factory-installed Circuit Breakers (included) 1/DP30
1/DP20
2/SP15
1/DP30
1/DP20
6/SP15
1/DP30
1/DP20
6/SP15
Max Load/Circuit
from Load Center
1/DP30 & DP20 or SP20 in all other spaces
Optional Power Inlets LL550F or L1430F
Optional Power Inlet Boxes PB50 or PB30
Min Recommended
Cord Size
6 Ga. (50A) or 10 Ga. (30A)
Conduit Length 18"
Conduit Trade Size 3/4" 1"

 

 

C US UL ListedAll Reliance Controls Corporation products are listed by Underwriters Laboratories Inc.

 

Reliance has several products. Only selected products are featured here. For information on additional Reliance products please check Reliance's website or request information from ESA.

Additional websites from Reliance Controls:
Reliance Labs - www.reliancelaboratories.com
The Home Protectors - www.home-protectors.com
Technical Support - http://support.reliancecontrols.com
Transfer Switch Safety - www.transferswitches.com

1131 Andover Park West * Seattle, WA 98188
Ph: 206-574-0092 * Fax: 206-575-0674 * repesa@repesa.com